Notifications
You must be signed in to change notification settings - Fork 10
MQTT API
Batcontrol provides an MQTT API that allows you to monitor and integrate your battery control system with other home automation platforms like Home Assistant. The MQTT interface publishes battery status, pricing information, and control states to configurable topics.
mqtt:
enabled: true
logger: false
broker: localhost
port: 1883
topic: house/batcontrol
username: user
password: password| Parameter | Type | Default | Description |
|---|---|---|---|
enabled |
boolean | false |
Enable or disable the MQTT API |
logger |
boolean | false |
Enable MQTT logging for debugging |
broker |
string | localhost |
MQTT broker hostname or IP address |
port |
integer | 1883 |
MQTT broker port (1883 for unencrypted, 8883 for TLS) |
topic |
string | house/batcontrol |
Base topic for all batcontrol MQTT messages |
username |
string | user |
MQTT broker username (if authentication required) |
password |
string | password |
MQTT broker password (if authentication required) |
mqtt:
retry_attempts: 5 # Number of connection retry attempts
retry_delay: 10 # Delay in seconds between retry attempts| Parameter | Type | Default | Description |
|---|---|---|---|
retry_attempts |
integer | 5 |
Number of times to retry connection on failure |
retry_delay |
integer | 10 |
Seconds to wait between retry attempts |
⚠️ Note: TLS/SSL support is currently untested. Use with caution in production environments.
mqtt:
tls: true
cafile: /etc/ssl/certs/ca-certificates.crt
certfile: /etc/ssl/certs/client.crt
keyfile: /etc/ssl/certs/client.key
tls_version: tlsv1.2| Parameter | Type | Default | Description |
|---|---|---|---|
tls |
boolean | false |
Enable TLS/SSL encryption |
cafile |
string | /etc/ssl/certs/ca-certificates.crt |
Path to Certificate Authority file |
certfile |
string | /etc/ssl/certs/client.crt |
Path to client certificate file |
keyfile |
string | /etc/ssl/certs/client.key |
Path to client private key file |
tls_version |
string | tlsv1.2 |
TLS version to use (tlsv1.2, tlsv1.3) |
Batcontrol supports Home Assistant's MQTT auto-discovery feature, which automatically creates entities in Home Assistant without manual configuration.
mqtt:
auto_discover_enable: true
auto_discover_topic: homeassistant| Parameter | Type | Default | Description |
|---|---|---|---|
auto_discover_enable |
boolean | true |
Enable Home Assistant auto-discovery |
auto_discover_topic |
string | homeassistant |
Base topic for auto-discovery messages |
When enabled, batcontrol will publish device and entity configuration messages to topics like:
homeassistant/sensor/batcontrol/battery_soc/confighomeassistant/sensor/batcontrol/current_price/confighomeassistant/binary_sensor/batcontrol/charging_active/config
Batcontrol publishes data to the following topic structure (assuming base topic house/batcontrol):
-
house/batcontrol/status- System status (online/offline) -
house/batcontrol/last_evaluation- Timestamp of last evaluation (Unix timestamp) -
house/batcontrol/evaluation_intervall- Evaluation interval in seconds
-
house/batcontrol/mode- Current operational mode:-
-1= Charge from Grid -
0= Avoid Discharge -
10= Discharge Allowed
-
-
house/batcontrol/charge_rate- Current charge rate in W -
house/batcontrol/discharge_blocked- Whether discharge is blocked (True/False)
-
house/batcontrol/SOC- State of Charge in % (formatted as 3-digit integer, e.g.,069) -
house/batcontrol/max_energy_capacity- Maximum battery capacity in Wh -
house/batcontrol/stored_energy_capacity- Energy stored in battery in Wh -
house/batcontrol/stored_usable_energy_capacity- Usable energy stored in battery in Wh (considering min SOC) -
house/batcontrol/reserved_energy_capacity- Energy reserved for discharge in Wh
-
house/batcontrol/always_allow_discharge_limit- Always discharge limit (0.0-1.0) -
house/batcontrol/always_allow_discharge_limit_percent- Always discharge limit in % -
house/batcontrol/always_allow_discharge_limit_capacity- Always discharge limit in Wh -
house/batcontrol/max_charging_from_grid_limit- Max charging from grid limit (0.0-1.0) -
house/batcontrol/max_charging_from_grid_limit_percent- Max charging from grid limit in %
-
house/batcontrol/min_price_difference- Minimum price difference in EUR (e.g.,0.050) -
house/batcontrol/min_price_difference_rel- Relative minimum price difference (e.g.,0.100) -
house/batcontrol/min_dynamic_price_difference- Dynamic price difference limit in EUR
-
house/batcontrol/FCST/production- Forecasted solar production in W -
house/batcontrol/FCST/consumption- Forecasted consumption in W -
house/batcontrol/FCST/prices- Forecasted electricity prices in EUR -
house/batcontrol/FCST/net_consumption- Forecasted net consumption in W
-
house/batcontrol/inverters/0/SOC- Inverter SOC in % -
house/batcontrol/inverters/0/stored_energy- Stored energy in Wh -
house/batcontrol/inverters/0/free_capacity- Free capacity in Wh -
house/batcontrol/inverters/0/max_capacity- Maximum capacity in Wh -
house/batcontrol/inverters/0/usable_capacity- Usable capacity in Wh -
house/batcontrol/inverters/0/max_grid_charge_rate- Max grid charge rate in W -
house/batcontrol/inverters/0/max_pv_charge_rate- Max PV charge rate in W -
house/batcontrol/inverters/0/min_soc- Minimum SOC setting -
house/batcontrol/inverters/0/max_soc- Maximum SOC setting -
house/batcontrol/inverters/0/capacity- Total capacity in Wh -
house/batcontrol/inverters/0/em_mode- Energy Manager mode (Fronius specific) -
house/batcontrol/inverters/0/em_power- Energy Manager power setting in W (Fronius specific)
Batcontrol listens to the following /set topics for remote control:
-
house/batcontrol/mode/set- Set operational mode (send-1,0, or10) -
house/batcontrol/charge_rate/set- Set charge rate in W (automatically sets mode to-1)
-
house/batcontrol/always_allow_discharge_limit/set- Set always discharge limit (0.0-1.0) -
house/batcontrol/max_charging_from_grid_limit/set- Set max charging from grid limit (0.0-1.0) -
house/batcontrol/min_price_difference/set- Set minimum price difference in EUR
-
house/batcontrol/inverters/0/max_grid_charge_rate/set- Set max grid charge rate in W -
house/batcontrol/inverters/0/max_pv_charge_rate/set- Set max PV charge rate in W -
house/batcontrol/inverters/0/em_mode/set- Set Energy Manager mode (Fronius: 0-2) -
house/batcontrol/inverters/0/em_power/set- Set Energy Manager power in W (Fronius specific)
-
house/batcontrol/inverters/0/SOC/set- Set SOC manually (0-100, testdriver only)
The forecast topics (/FCST/*) publish JSON data with the following structure:
{
"data": [
{
"time_start": 1696435200,
"value": 2500.5,
"time_end": 1696438800
},
{
"time_start": 1696438800,
"value": 3200.0,
"time_end": 1696442400
}
]
}Where:
-
time_start- Unix timestamp for start of hour -
time_end- Unix timestamp for end of hour -
value- Forecasted value (W for production/consumption, EUR for prices)
mqtt:
enabled: true
broker: 192.168.1.100
port: 1883
topic: energy/batcontrolmqtt:
enabled: true
broker: mqtt.example.com
port: 1883
topic: home/energy/batcontrol
username: batcontrol_user
password: secure_password_here
retry_attempts: 3
retry_delay: 5mqtt:
enabled: true
broker: homeassistant.local
port: 1883
topic: batcontrol
username: mqtt_user
password: mqtt_password
auto_discover_enable: true
auto_discover_topic: homeassistantmqtt:
enabled: true
broker: secure-mqtt.example.com
port: 8883
topic: batcontrol
username: secure_user
password: secure_password
tls: true
cafile: /path/to/ca-cert.pem
certfile: /path/to/client-cert.pem
keyfile: /path/to/client-key.pem
tls_version: tlsv1.3-
Connection Failed
- Check broker hostname/IP and port
- Verify network connectivity
- Check username/password if authentication is enabled
-
Messages Not Appearing
- Verify the topic configuration
- Check broker logs for rejected messages
- Ensure proper permissions for the MQTT user
-
Home Assistant Auto-Discovery Not Working
- Verify
auto_discover_enable: true - Check that Home Assistant MQTT integration is configured
- Ensure the discovery topic matches Home Assistant configuration
- Verify
Enable MQTT logging for troubleshooting:
mqtt:
enabled: true
logger: true # Enable debug loggingThis will provide detailed information about MQTT connections, published messages, and any errors in the batcontrol log files.
- Always use authentication (
username/password) in production - Consider using TLS encryption for remote connections (though currently untested)
- Limit MQTT user permissions to only necessary topics
- Use strong, unique passwords for MQTT authentication