@@ -10,19 +10,19 @@ blueprint:
1010 entity :
1111 domain : binary_sensor
1212 energy_diversion :
13- name : Energy Diversion
13+ name : Energy Diversion (solar_router.regulator_opening)
1414 description : " Sensor for current energy diversion percentage"
1515 selector :
1616 entity :
1717 domain : number
1818 energy_sent_to_grid :
19- name : Energy Sent to Grid
19+ name : Energy Sent to Grid (solar_router.real_power)
2020 description : " Sensor for energy being sent to the grid (Ex: use real_power of your solar router)"
2121 selector :
2222 entity :
2323 domain : sensor
2424 solar_router :
25- name : Solar Router
25+ name : Solar Router (solar_router.activate)
2626 description : " Switch entity for the solar router"
2727 selector :
2828 entity :
@@ -74,6 +74,8 @@ blueprint:
7474 unit_of_measurement : " seconds"
7575
7676trigger :
77+ - platform : event
78+ event_type : automation_reloaded
7779 - platform : state
7880 entity_id : !input ev_connected
7981 - platform : numeric_state
@@ -89,7 +91,7 @@ trigger:
8991
9092action :
9193 - choose :
92- # Condition 2 : Activate solar router when EV disconnected
94+ # Condition 1 : Activate solar router when EV disconnected
9395 - conditions :
9496 - condition : state
9597 entity_id : !input ev_connected
@@ -98,7 +100,7 @@ action:
98100 - service : switch.turn_on
99101 target :
100102 entity_id : !input solar_router
101- # Condition 1 : Deactivate solar router when EV need to be recharged
103+ # Condition 2 : Deactivate solar router when EV need to be recharged
102104 - conditions :
103105 - condition : state
104106 entity_id : !input ev_connected
@@ -112,18 +114,25 @@ action:
112114 - condition : numeric_state
113115 entity_id : !input energy_sent_to_grid
114116 above : !input excess_energy_threshold
117+ for :
118+ seconds : !input delay_before_deactivation
115119 sequence :
116120 - service : switch.turn_off
117121 target :
118122 entity_id : !input solar_router
119123 # Condition 3: Reactivate solar router when EV battery is full
120124 - conditions :
121- - condition : numeric_state
122- entity_id : !input energy_sent_to_grid
123- above : !input max_energy_sent
125+ - condition : state
126+ entity_id : !input ev_connected
127+ state : " on "
124128 - condition : state
125129 entity_id : !input solar_router
126130 state : " off"
131+ - condition : numeric_state
132+ entity_id : !input energy_sent_to_grid
133+ above : !input max_energy_sent
134+ for :
135+ seconds : !input delay_before_activation
127136 sequence :
128137 - service : switch.turn_on
129138 target :