Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathObsSim_UnitStatus.txt
More file actions
157 lines (139 loc) · 3.77 KB
/
ObsSim_UnitStatus.txt
File metadata and controls
157 lines (139 loc) · 3.77 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
This file is the start of a location/maintenance status record for the Observatory Simulators.
ObsSim #001:
Location: Bldg 37 (Joel V.)
Firmware Loaded: 1.7d
Power Supply Configuration:
+5 - Vpt DVHF2805S
-12 - Vpt DVHF2812S
+15 - Vpt DVHF2815S
Assembly/Mech. Issues:
Unit has prototype frame trigger out option installed (FPE2)
Missing SN label
Missing front panel graphic
Reported the FPE1 interface does not work (using FPE2)
ObsSim #002:
Location: Bldg 37 (Jerry Roberts)
Firmware Loaded: 1.7b
Power Supply Configuration:
+5 - Vpt DVHF2805S
-12 - Vpt DVHF2812S
+15 - Vpt DVHF2815S
Assembly/Mech. Issues:
Missing SN label
ObsSim #003:
Location: NE83 (Ed Bokhour)
Firmware Loaded: 1.7d
Power Supply Configuration:
+5 - Vpt DVHF2805S
-12 - Vpt DVHF2812S
+15 - Vpt DVHF2815S
Assembly/Mech. Issues:
Missing SN label
ObsSim #004:
Location: Next to Pony
Firmware Loaded: 1.7d
Zynq PCB Version: 1.2 (SN 603651211452-34271)
Power Supply Configuration:
+5 - Vpt DVHF2805S
-12 - Vpt DVHF2812S
+15 - Vpt DVHF2815S
Assembly/Mech. Issues:
None
ObsSim #005:
Location: Jerry Roberts (37)
Firmware Loaded:1.7d
Zynq PCB Version: 2.0 (SN 698951521529-43704)
Power Supply Configuration:
+5 - Vpt DVHF2805S
-12 - Vpt DVHF2815S (Note: -15V supply substitution)
+15 - Vpt DVHF2815S
Assembly/Mech. Issues:
Replaced feet - No other issues
ObsSim #006:
Location: Alexander Rudat (?)
Firmware Loaded: 1.7b
Zynq PCB Version: 2.0 (SN 698951521529-43416)
Power Supply Configuration:
+5 - Vpt DVHF2805S
-12 - Vpt DVHF2815S (Note: -15V supply substitution)
+15 - Vpt DVHF2815S
Assembly/Mech. Issues:
None
ObsSim #007:
Location: Pony 2 (Steve Kissel)
Firmware Loaded: 1.7d
Zynq PCB Version: 2.0 (SN 698951631540-45231)
Power Supply Configuration:
+5 - TDK/Lambda PXD2024S05
-12 - TDK/Lambda PXD2024S12
+15 - TDK/Lambda PXD2024S15
Assembly/Mech. Issues:
Unit has prototype frame trigger out option installed (FPE1)
ObsSim #008:
Location: Kari's Office (ADHU devel./test)
Firmware Loaded: Various ADHU Test versions based on 1.7d software
Zynq PCB Version: 2.0 (SN 698951631540-45405)
Power Supply Configuration:
+5 - TDK/Lambda PXD2024S05
-12 - TDK/Lambda PXD2024S12
+15 - TDK/Lambda PXD2024S15
Assembly/Mech. Issues:
ObsSim #009:
Location: Lab bench LHS of Cosmos
Firmware Loaded: 1.7f
Zynq PCB Version: 2.0 (SN 698951631540-45218)
Power Supply Configuration:
+5 - TDK/Lambda PXD2024S05
-12 - TDK/Lambda PXD2024S12
+15 - TDK/Lambda PXD2024S15
Assembly/Mech. Issues:
ObsSim #10:
Location: GSE Equipment Locker
Firmware Loaded: 1.7d
Zynq PCB Version: 2.0 (SN 698951631540-45312)
Power Supply Configuration:
+5 - TDK/Lambda PXD2024S05
-12 - TDK/Lambda PXD2024S12
+15 - TDK/Lambda PXD2024S15
Assembly/Mech. Issues:
ObsSim #11:
Location: GSE Equipment Locker
Firmware Loaded: 1.7d
Zynq PCB Version: 2.0
Power Supply Configuration:
+5 - TDK/Lambda PXD2024S05
-12 - TDK/Lambda PXD2024S12
+15 - TDK/Lambda PXD2024S15
Assembly/Mech. Issues:
ObsSim #12:
Location: GSE Equipment Locker
Firmware Loaded: 1.7d
Zynq PCB Version: 2.0
Power Supply Configuration:
+5 - TDK/Lambda PXD2024S05
-12 - TDK/Lambda PXD2024S12
+15 - TDK/Lambda PXD2024S15
Assembly/Mech. Issues:
ObsSim #13:
Location: GSE Equipment Locker
Firmware Loaded: 1.7d
Zynq PCB Version: 2.0
Power Supply Configuration:
+5 - TDK/Lambda PXD2024S05
-12 - TDK/Lambda PXD2024S12
+15 - TDK/Lambda PXD2024S15
Assembly/Mech. Issues:
ObsSim #14:
Location: GSE Equipment Locker
Firmware Loaded: 1.7d
Zynq PCB Version: 2.0
Power Supply Configuration:
+5 - TDK/Lambda PXD2024S05
-12 - TDK/Lambda PXD2024S12
+15 - TDK/Lambda PXD2024S15
Assembly/Mech. Issues:
New Zynq boards:
Zynq PCB Version: 2.0 (SN 698951881608-50229)
Zynq PCB Version: 2.0 (SN 698951881608-50265)
Zynq PCB Version: 2.0 (SN 698951881608-50294)
Zynq PCB Version: 2.0 (SN 698951881608-50268)