Description

@gjcoram

The variables VS, VD, VG, are declared in two places:

  1. ekv3_include/ekv3_variables_oppoint.va, lines 12-14
  2. ekv3_include/ekv3_variables.va, lines 171-173

The oppoint file is included at module scope (outside the "analog" block), and then the other file is included inside a block named EKV3 (see excerpt from ekv3.va below). The variables are only set in the block EKV3, which means the code is setting the second set of variables, and the operating-point variables are never given values. This is the reason why VAMPyRE complains that the op-pt variables are never set.

ERROR in file ekv3_include/ekv3_variables_oppoint.va, line 12: Operating-point variable 'VS' was never assigned a value
ERROR in file ekv3_include/ekv3_variables_oppoint.va, line 13: Operating-point variable 'VD' was never assigned a value
ERROR in file ekv3_include/ekv3_variables_oppoint.va, line 14: Operating-point variable 'VG' was never assigned a value

//include "ekv3_include/ekv3_variables.va" include "ekv3_include/ekv3_functions_def.va"
include "ekv3_include/ekv3_parameters.va" include "ekv3_include/ekv3_variables_oppoint.va"
analog begin

////////////////////////////////////////////////////////////////////////////////
// LEVEL 0 //
// MODEL LEVEL CALCULATIONS //
////////////////////////////////////////////////////////////////////////////////
begin:EKV3
include "ekv3_include/ekv3_variables.va" MODEL
begin